看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Off-Design Performance of Gas Turbi... 收藏
Off-Design Performance of Gas Turbine Power Units with Alternative Load-Control Strategies

Off-Design Performance of Gas Turbine Power Units with Alternative Load-Control Strategies

作     者:Zhiqiang Pan Zhiwen Lin Kunle Fan Cheng Yang Xiaoqian Ma 

作者机构:Guangzhou Zhujiang LNG Power Generation Co.Ltd.Guangzhou511457China School of Electric PowerSouth China University of TechnologyGuangzhou510640China 

基  金:This work was supported by Guangdong Province Key Laboratory of Efficient and Clean Energy Utilization(2013A061401005) by Guangdong Basic and Applied Basic Research Foundation(2020A1515011103) by research fund from Guangzhou Development Group Co.,Ltd 

出 版 物:《Energy Engineering》 (能源工程(英文))

年 卷 期:2021年第118卷第1期

页      码:119-141页

摘      要:Gas turbine power units,as an effective way to cope with the severe challenge of renewable energy accommodation in power grids,arouse the interest of power enterprises in the deep peak-load regulation *** common alternative load-control strategies including constant turbine inlet temperature(TIT)and constant turbine exhaust temperature(TET)regulations were taken into *** comparatively investigate the part-load performance under these strategies,both mathematical and physical models were set up successively to serve as a validation and complementary to each *** the mathematical model of compressor with inlet guide vane(IGV),combustor and turbine,stage-stacking method based on blade average geometric parameter,energy conservation and turbine stage model were adopted *** the physical model,design and off-design analysis were carried out based on GT PRO and THERMOFLEX *** simulation result of mathematical model validated the reliability of the physical *** on this,the influence of ambient temperature and different load-regulating strategies on the off-design performance of gas turbine power units was studied in *** results in the case of a PG 9351FA gas turbine show that the ambient temperature has a great impact on system performance,i.e.,every 5℃ increase in the ambient temperature produces a reduction of 3.7%in the relative full-load output and 1.1%in the relative efficiency respectively;when the gas turbine operates under constant TIT strategy,TET starts to rise till it reaches the maximum allowable value with the load rate decreasing,and IGV keeps at the minimum angle with both TIT and TET decreasing when the load rate is lower than 65%;when the gas turbine operates under constant TET strategy,TIT drops slightly at load rate of above 60%while both TIT and TET evidently decrease below 60%load rate operating along the constant corrected speed line at the minimum allowable IGV opening;gas

主 题 词:Gas turbine part load performance operating strategy comparative simulation 

学科分类:0401[教育学-教育学类] 04[教育学] 

核心收录:

D O I:10.32604/EE.2020.013585

馆 藏 号:203102145...

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分