文献详情 >Design and testing of micro-tribome... 收藏
Design and testing of micro-tribometer with macro applied load

Design and testing of micro-tribometer with macro applied load

作     者:XU HongYi ZHANG ChenHui WU Pu 

作者机构:State Key Laboratory of Tribology Tsinghua University Shenzhen Key Laboratory of Micro-nano Manufacturing Research Institute of Tsinghua University in Shenzhen 

基  金:supported by National Natural Scienceof China(Grant Nos.51527901,51335005&51321092) National Basic Research Program of China(Grant No.2013CB934200) 

出 版 物:《Science China(Technological Sciences)》 (中国科学(技术科学英文版))

年 卷 期:2016年第59卷第11期

页      码:1666-1672页

摘      要:With the development of superlubricity, the requirement for the accuracy of measuring super low friction force becomes more and more high. In this study, a novel micro-tribometer has been designed. The resolution and accuracy of friction force are 0.01 m N by using the dual frequency laser interferometer. Experiments were performed to investigate the ability of measuring friction force from different aspects. The interference signal mixed in the measured friction force curve was analyzed and can be removed by a designed filter. The results of experiment show that the tribometer is capable of measuring a super low friction force in the order of magnitude of 0.01 m N with an applied load up to 1 N.

主 题 词:friction test methods dual-frequency laser interferometer bender piezo actuator 

学科分类:08[工学] 080401[080401] 0804[工学-材料学] 081102[081102] 0811[工学-水利类] 

核心收录:

D O I:10.1007/sl1431-016-0351-4

馆 藏 号:203208758...

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分