看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Refining bioreactor design using au... 收藏
Refining bioreactor design using autoclavable glass bonding

Refining bioreactor design using autoclavable glass bonding

作     者:Cornelia Bahr Elisabeth Stammen Sarah Zahlten Stefan Bohm Klaus Dilger Jochen Büchs 

作者机构:AVT-Biochemical EngineeringRWTH Aachen UniversityAachenGermany Institute of Joining and WeldingTechnische Universitat BraunschweigBraunschweigGermany Institute of Production Technology and LogisticsKassel UniversityKasselGermany 

基  金:funded by the German Federal Ministry of Economics and Technology in Berlin via the German Federation of Industrial Research Associations“Otto von Guericke”e.V.(AiF)in Cologne(AiF 14487 N) was supported by the research association of DECHEMA e.V.(the Society for Chemical Engineering and Bio-technology) 

出 版 物:《Advances in Bioscience and Biotechnology》 (生命科学与技术进展(英文))

年 卷 期:2011年第2卷第4期

页      码:233-243页

摘      要:Selecting the right design of bioreactors is crucial for guaranteeing the reproducibility of bioprocesses. Up to now, conventionally designed bioreactors consist typically of melted or clamped joints. Since melting of borosilicate glass leads to large deformed areas along the joint, the desired geometric reproducibility is not ensured. Moreover, clamping complicates and greatly restricts the bioreactor design. Bonding, however, is advantageous in that it does not alter the material joined and it is easy to use. Furthermore, it has been recently shown that specially developed glass bonding techniques withstand multiple autoclaving cycles. The current research investigated practice-relevant parameters influencing the lifespan of epoxy-or (urethane) acrylate-bonded glass bioreactors. Hereby, the influence of cleaning and sensitivity to fermentation compounds (ethanol and acetic acid) was quantified using glass-glass and glass-stainless steel specimens. Whereas cleaning did not adversely affect the durability of glass bonds, high concentrations of the fermentation compounds ethanol and acetic acid resulted in accelerated corrosion and subsequent bond failure. Moreover, no effect of eight different epoxy and (urethane) acrylate adhesives was observed on selected model organisms Escherichia coli K12 and Hansenula polymorpha wild type. Another objective of this study was to refine the design of two small-scale bioreactors (ca. 250 mL) by replacing clamps and melted joints by adhesive joints. It was found that the bonded bioreactors yielded a higher geometric reproducibility than that of conventional melted or clamped ones. In conclusion, bonded glass joints greatly enhance the geometric reproducibility of bioreactors and, in turn, the reproducibility of bioprocesses. As glass bonding is easy to handle, it opens up new opportunities to design bioreactors that had been previously too expensive and complicated.

主 题 词:Bioreactor Durability Borosilicate Glass Stainless Steel 1.4301 Epoxy Adhesive Acrylate Adhesive 

学科分类:1002[医学-临床医学类] 100214[100214] 10[医学] 

D O I:10.4236/abb.2011.24034

馆 藏 号:203219950...

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分