文献详情 >Design and biomechanical study of a... 收藏
Design and biomechanical study of a modified pedicle screw

Design and biomechanical study of a modified pedicle screw

作     者:刘洪 郑文杰 李长青 刘国栋 周跃 

作者机构:Department of Orthopaedics Xinqiao Hospital Third Military Medical University Chongqing 400037 China Research Institute of Surgery Daping Hospital Third Military Medical University Chongqing 400042 China 

出 版 物:《Chinese Journal of Traumatology》 (中华创伤杂志(英文版))

年 卷 期:2010年第13卷第4期

页      码:222-228页

摘      要:Objective: In pedicle screw fixation, the heads of monoaxial screws need to be directed in the same straight line to accommodate the rod placement by backing out during operation, which decreases the insertional torque and internal fixation strength. While polyaxial screws facilitate the assembly of the connecting rod, but its ball-in-cup locking mechanism reduces the static compressive bending yield strength as compared with monoaxial screws. Our study aimed to assess the mechanical performance of a modified pedicle screw. Methods: In this study, the tail of the screw body of the modified pedicle screw was designed to be a cylindershaped structure that well matched the inner wall of the screw head and the screw head only rotated around the cyclinder. Monoaxial screws, modified screws and polyaxial screws were respectively assembled into 3 groups ofvertebrectomy models simulated by ultra high molecular weight polyethylene (UHMWPE) blocks. This model was developed according to a standard for destructive mechanical testing published by the American Society for Testing Materials (ASTM F1717-04). Each screw design had 6 subgroups, including 3 for static tension, load compression and torsion tests, and the rest for dynamic compression tests. In dynamic tests, the cyclic loads were 25%, 50%, and 75% of the compressive bending ultimate loads respectively. Yield load, yield ultimate load, yield stiffness, torsional stiffness, cycles to failure and modes of failure for the 3 types of screws were recorded. The results of modified screws were compared with those ofmonoaxial and polyaxial screws. Results: In static tests, results of bending stiffness, yield load, yield torque and torsional stiffness indicated no significant differences between the modified and monoaxial screws (P〉0.05), but both differed significantly from those ofpolyaxial screws (P〈0.05). In dynamic compression tests, both modified and monoaxial screws showed failures that occurred at the insertion point

主 题 词:Bone screws Biomechanics Spine Internal fixators 

学科分类:1004[医学-公共卫生预防医学类] 08[工学] 080104[080104] 0815[工学-矿业类] 0801[工学-力学类] 10[医学] 

D O I:10.3760/cma.j.issn.1008-1275.2010.04.006

馆 藏 号:203369262...

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分